EasyManua.ls Logo

Alde Compact 3010 - Troubleshooting; Important Information

Alde Compact 3010
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
US/CAN
TROUBLESHOOTING
Iftheboilerisequippedwithadigitalcontrolpanel,
alwaysstartbycheckinganyerrormessages.
(Seesection11operatinginstructioncontrolpanel)
The boiler does not start on Gas:
1. ChecktomakesurethatthereisgasintheLPGas
tank.Ifitisempty,havethetankrelled.
2. Checktomakesurethatthemaingasvalveisfully
open.Ifnot,openthegasvalvealltheway.
3. Checkthattheboilerisconnectedtotheelectricity
supply(>11VDC).
4. Checkthatthe12Vfusefortheboilerisintact.
5. Checkwhethertheelectricconnectionsontheboiler
aresecurelyinposition.
Ifnoneoftheabovehelps,contactaserviceworkshop.
The electric heating element is not working:
1. Checkthatthereisanelectricitysupply(120V~)to
thevehicle.
2. Checkthattherelaysttedtotheboilercomeon(a
slightclickcanbeheardfromtherelayswhenthe
heatingelementisswitchedonatthecontrolpanel).
Ifnoneoftheabovehelps,contactaserviceworkshop.
Control Panel is not working-Emergency start and
operation:
IftheControlPanelstopsworking,itispossibletostart
theheatermanually,toprovideemergencyheatuntil
repairscanbemadebyaservicetechnician.Followthe
instructionsbelow.Formoredetailsandanillustration,
seeSection12oftheControlPanelinstructions.
1. Disconnect12Vandthecabletothepanelonthe
heater.
2. Connectacablebetween2and9inthecontact
device(ontheheater)(Seechapter12).
3. Connect12Vtotheheater.
4. Nowtheheaterstartswithgasand1kW.
(Regulationofroomtemperaturedoesnotfunction;
thepumpoperatesconstantly.)
NOTICE
If the boiler has not been operated for some time,
or if the gas cylinder has been changed, it may take
longer than normal to light the boiler.
DANGER
FARA
DANGER
GEFAHR
FARE
VAARA
PELIGRO
PERICOLO
GEVAAR
SHOCK HAZARD
The 120V electrical service presents a risk of elec-
trical shock. Do not attempt to service the electric
heating element yourself.
IMPORTANT INFORMATION
Alwaysswitchoffthemainisolatingswitchforthe
boilerwhenthevehicleisnotinuse.
Whenwashingthevehicle,donotspraywaterdirectly
towardstheue.
Whencampinginwinterconditions,ensuretheue
andexhaustairvalvesarekeptclearofsnowandice.
YoumayusetheboilertoheattheRVwithoutlling
thewaterheater.
TheLPGasboilerandelectricelementmaybeoper-
atedsimultaneously.
Alwaysdrainthehotwaterheateroffreshwaterwhen
thereisariskoffrostandwhenthevehicleisnotbeing
used.
TheLPGasboilermustnotbeinoperationwhenrefu-
ellingthevehicle.
Neverallowtheheatingsystemtostandemptyof
ethyleneglycoluid.
Checksupplyandexhaustairintake,thevehicleis
oftenequippedwithsupplyandexhaustairvalves
(refertovehicleinstructions)thatmustnotbeblocked
asthiswillimpairtheefciencyoftheheatingsystem
andairquality,whichcanleadtocarbonmonoxide
poisoning.
NB! Close the main LP Gas valve in the following
circumstances.
Whenthevehicleisnotbeingused
TurnOFFLPGassupplytankwhenvehicleisinmo-
tion.Thisdisablesallgasappliancesandpilotlights.
Gasappliancesmustneverbeoperatedwhilevehicle
isinmotion.
Whenrepairingtheboiler.
WhenleaksintheLPGassystemaresuspected.

Table of Contents