Dribble Vibration
Selects the rate of vibration during the second, dribble stage fill. Greater speeds (higher
entries) will result in more product.
This selection is accessed from the Setup Vibration screen.
Factory Setting: 0.00
Valid Entries: 5.00-100.00
Minimum Fill Time
Specifies the minimum time for a fill cycle used to identify problems or faults. If the fill time
does not attain this minimum value, an error message is generated indicating a possible
problem.
The Minimum Fill Time should be set at a point where unacceptable weight containers occur
(below minimum allowable tolerance).
This selection is accessed from the Setup Vibration screen.
Factory Setting: 0.000
Valid Entries: 0.000-9.999
Maximum Fill Time
Specifies a maximum time allowable for a fill cycle used to identify problems or faults. If the
fill time exceeds this value, an error message is generated indicating a possible problem.
The Maximum Fill Time should be set where undue product spillage occurs by overfilling.
This selection is accessed from the Setup Vibration screen.
Factory Setting: 0.000
Valid Entries: 0.000-30.000
Drop Time
Specifies the time required for product to drop into the discharge nozzle. The entry will vary
according to the type of product, overall accuracy levels, and desired production rates.
This selection is accessed from the Setup Vibration screen.
Factory Setting: 0.000
Valid Entries: 0.000-9.999