4. How to Operate Screens
4-11
(g) STEP #
The present number of steps is displayed when STEPPER MODE is activated
on the MODE SELECT screen. (In the example above, the VALVE 1 is set to
STEP 1, the VALVE 2; STEP 3.)
(h) STEPPER COUNT
The number of welds in the present step is displayed when STEPPER MODE
(see (7)(f)) is activated on the MODE SELECT screen.
(i) WELD COUNT
The present number of welds is displayed when the WELD COUNT (see (7)(g))
is activated on the MODE SELECT screen.
(Note) Monitored value
Only the last monitored value and the number of counts of each
SCHEDULE are kept for a period of 10 days after the power is turned off.
When the repetition welding is performed with PULSATION or OFF time
setting, only the last data is displayed as the monitored value. The passing
data is not displayed.