IS-200A
4. How to Operate Screens
4-28
(11) RESET TO DEFAULT Screen
This screen is used to initialize the Power Supply’s memory (i.e., to restore the
initial settings).
Initialization will not clear the memory of the MA-627A.
To initialize, move the cursor (>) over YES or NO and press the [ENTER] key.
RESET POWER SUPPLY BACK
TO FACTORY DEFAULTS?
YES
NO
WARNING!
IF YES IS ENTERED THE POWER SUPPLY WILL
ERASE ALL SCHEDULE DATA!
(a) YES
Initializes the Power Supply memory (restores the initial settings).
After initialization, the screen will reflect the settings shown in this
chapter.
(b) NO
Returns the display to the MENU screen without initializing the
Power Supply memory.
(12) PROGRAM PROTECT MODE Screen
When this function is used, set values cannot be changed by any person other than
the supervisor.
PROGRAM PROTECT is usually set to OFF. When it is set to ON, set values
cannot be changed until PROGRAM PROTECT is set to OFF again.
Follow the procedure below to change the setting of PROGRAM PROTECT.
Turn on the power supply with the [▽ (DOWN)] key pressed or connect the
MA-627A to the circuit cable with the power supply turned on. The following
screen is displayed.
-PROGRAM PROTECT MODE
PROGRAM PROTECT 0FF
When the [ENTER] key is pressed after the [+ON] key is pressed, ON is
displayed.
You cannot go to other screens from this screen. Also, the external signals
cannot be received.
(a)
(b)