EasyManua.ls Logo

Amada IS-200A - Data Code Table

Default Icon
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IS-200A
10. External Communication Function
10-6
(5) Data Code Table
Screen 01 (SCHEDULE data)
Specific data in accordance with Schedule No. (Schedule No.: 001 to 255)
Item Contents
Character
String
Range
1 Control mode n,
0 to 5
0: Primary constant-current
effective value control
1: Secondary constant-current
effective value control
2: Secondary constant-power
effective value control
3: Primary constant-current peak
value control
4: Secondary constant-voltage
effective value control
5: Constant-phase control
2 Unit of time
(*1)
n,
m: ms
C: CYC
3 SQD / Squeeze delay time nnnn,
0000 to 9999 (ms mode)
0000 to 0999 (CYC mode)
4 SQZ / Squeeze time nnnn,
0000 to 9999 (ms mode)
0000 to 0999 (CYC mode)
5 UP1 / Upslope 1 time nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
6 WELD1 / Weld 1 time nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
7 DOWN1 / Downslope 1 time nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
8 COOL1 / Cooling 1 time nnn,
000 to 999(ms mode)
000 to 099(CYC mode)
9 UP2 / Upslope 2 time nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
10 WELD2 / Weld 2 time nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
11 DOWN2 / Downslope 2 time nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
12 COOL2 / Cooling 2 time nnn,
000 to 999 (ms mode)
000 to 099 (CYC mode)
13 UP3 / Upslope 3 time nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
14 WELD3 / Weld 3 time nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
15 DOWN3 / Downslope 3 time nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
16 HOLD / Hold time nnnnn,
00000 to 20000 (ms mode)
00000 to 00999 (CYC mode)
17 OFF / Off time nnnn,
0000 to 9990 (ms mode)
(*2)
0000 to 0099 (CYC mode)
18 HEAT1
n.nn, 0.10 to 9.99 (kA, kW, V)
nn.n, 10.0 to 99.9 (%)
19 HEAT2
n.nn, 0.10 to 9.99 (kA, kW, V)
nn.n, 10.0 to 99.9 (%)

Related product manuals