63AV 70 X
OPERATION MANUAL
How to start via cables from external power source:
Starting voltage from external power source shall be the voltage of 12V.
Follow unconditionally the operation sequence below.
1/ Connect one end of (+) cable pole to (+) pole of the battery discharged.
2/ Connect second end of (+) cable pole to (+) pole.
3/ Connect one end of (–) cable pole to (–) pole of external battery.
4/ Connect the second end of (–) cable pole to such part of started Machine which is x-wired with the engine (or with the engine
block itself).
When started, disconnect the battery jump cables in reverse order.
Do not connect (–) pole cable to (–) pole of discharged battery of the Machine being started! There is
risk of strong sparking in course of starting followed by explosion of battery-generated gas.
Make sure the non-insulated parts of the battery jump cable clamps do NOT contact each other!
Make sure the jump cable connected to (+) pole of the battery does NOT come into contact with electri-
cally conductive parts of the Machine – danger of short circuit!
Do NOT lean over the battery – risk of electrolyte burn!
Rule out any presence of ammable sources (open ame, burning cigarettes, etc.)
Do NOT conrm voltage presence in a wire through sparking via Machine frame!