L0118G
3-4
Dividers
The dividers separate product columns on the tray. To
remove the divider, push rearward and lift. To install,
insert the rear tab in the desired slot, push rearward
and then down. Make sure the locking tabs on the
bottom have engaged their respective slots and pull
forward. Bottle tray dividers are held in place with
screws.
Candy Pusher Bar
On snack trays, 2 horizontal slots in the divider allow
for the installation of a candy pusher bar. The candy
pusher bar keeps items pushed to one side of the
column. This is typically used with tall products. The
candy pusher bar is removed by pulling the bar free
from the plastic clips. To reinstall, it is easiest to
squeeze the bar into the clip using pliers (Refer to
Section 5.14).
3.8 ELECTRICAL PANEL
The electrical panel is located in the recess formed by
the right rail mount on the right side of the cabinet,
behind an access panel.
Power Switch
The power switch is located on the lower right rail
mount near the fuse. The power switch is used to
disconnect 24VAC power to the control board.
Note: The power should be shut off when MDB devices
are being connected or disconnected, when the board is
being serviced, or before any wiring harness is
connected to or disconnected from the control board or
sensors.
Fuse Holder
The fuse holder is located on the lower right rail
mount near the refrigeration unit power outlet. It
contains a 3 amp fast-blow fuse to protect the 24 VAC
power supply to the control board. A spare fuse is
stored in the cover. The fuse holder is opened by
pressing in and down on the indicated side of the
cover and pulling out.
Transformers
The transformer reduces the input voltage to 24 volts
AC for the control board. An optional 2
nd transformer
supplies power to the window heater.
RFI Filter
The filter removes electrical noise from the power
supplied to the 24VAC transformer to prevent
interference with operation of the control board and
software.
Relay
AMS relays use a 24 VDC signal from the control
board to actuate the relay and supply power to the
refrigeration unit or other accessories.
Ballast
The ballast provides the necessary power to the
optional fluorescent lamp in the door.
Power Distribution Harness
The power distribution harness splits the incoming
power into individual leads for the high voltage
components.
Ground Attachment
The vendor electrical ground is made through the use
of grounding studs or screws at the lower back wall of
the right rail mount. Earth ground and individual
ground wires from the high voltage components are
attached here,
and should always be replaced
after service or repair.
3.9 POWERED VENTILATION SYSTEM
(OPTIONAL)
On vendors equipped with a powered ventilation
system, a continuously running fan circulates air
through the vendor and exhausts through the back of
the cabinet.
3.10 1.5” HELIX TRAY (OPTIONAL)
The 1.5” Helix Tray is mounted below the bottom
snack tray. To load the tray with small products such
as gum and mints, grasp the tray and pull forward to
unsnap the catches. After loading, push the tray to the
rear until the catches snap in place.
The motors in the 1.5” Helix Tray operate in the same
way as snack or bottle tray motors (Refer to Section
5.15).