L0118G
4-2
LES UTILITES ELECTRIQUES NECESSAIRE
POUR CONFORMEMENT
AUX REGLES CE:
CET EQUIPEMENT NE DOIT UTILISER QUE SUR
LES LIEUX AVEC UNE CAPACITE DU COURANT
AU MOINS 100A LA PHASE, FOURNIE A UN
RESEAU DE DISTRIBUTION AVEC UN VOLTAGE
NOMINAL DE 400/230V. LA PERSONNE QUI SE
DETERMINER PENDANT UNE CONSULTATION
AVEC L’ADMINISTRATION DU SECTEUR, S’IL
FAUT, QUE LA CAPACITE DE COURANT AU
POINT D’INTERFACE EST ASSEZ POUR CET
EQUIPEMENT.
4.2 VENDOR PREPARATION
Inspection
Inspect the vendor carefully for shipping damage prior
to signing the carrier’s delivery receipt. Check for
dents on the top or sides of the vendor, bent legs,
broken glass, or other damage on the exterior of the
machine. Check the interior for components that may
have been knocked loose or other damage.
Mounting and Connecting Bill Validators and Card
Readers
The AMS vendor will support any NAMA-approved
Multi-Drop Bus (MDB) bill validator or card reader.
Please read the device manufacturer’s literature
before proceeding.
1. Always disconnect power to the control board
before servicing.
2. On the inside of the main door, locate and open
the access doors on the left side. Locate the
white plastic coin chute which leads from the coin
slot on the front of the door. Above the coin chute
are (2) metal plates, each fastened to a set of (4)
threaded mounting studs which correspond to the
mounting holes in the bill validator. Either set of
mounting studs may be used for a bill validator or
card reader. The lower mounting position will
allow the machine to meet the 1991 ADA side
reach requirements for consumers with
disabilities.
3. Remove the four nuts that retain the steel cover
panel. Remove the steel cover panel, then press
out the plastic cover panel in the escutcheon.
4. Refer to the manufacturer’s literature for
instructions on accessing the mounting holes in
your device. Place the mounting holes over the
threaded studs and reinstall the nuts. Some
devices may require spacers, which are available
from AMS (Part Number 20258).
Mounting and Connecting Coin Changer
The AMS vendor will support any NAMA-approved
Multi-Drop Bus (MDB) Coin Changer. On some export
models, Executive-type Changers are supported as
well. Please read the manufacturer’s literature before
proceeding.
1. Always disconnect power to the control board
before servicing.
2. On the inside of the main door, locate and open
the access doors on the left side. Locate the
white plastic coin chute which leads from the coin
slot on the front of the door. Below the coin chute
are (3) screws which correspond to slots on the
back of the changer. Do not adjust these screws.
3. Install the changer by placing the large round
opening at the bottom of each slot over a screw
head. Be careful to hold the wiring harnesses in
this area out of the way. Once each of the round
openings are over the screw heads, the changer
is lowered to engage the narrow portion of the
slot with the shank of each screw.
4. Tighten the mounting screws (reference
manufacturer’s literature).
5. Adjust the white plastic coin chute as required to
align the chute with the changer.
Connecting the MDB Devices
Note: Always disconnect power to the control
board before servicing.
If your vendor is equipped with LED lighting, the MDB
Harness from the Control Board must connect directly
to the LED connector. If there are dual LED’s to be
connected, connect first to one LED and then connect
the second LED into the free connector of the first. If
the LED’s are not the first items connected to the
Control Board, they will not be dimmable.
Connect the Card Reader (if present), to the LED’s
free connector – or directly to the Control Board if no
LED lighting is present - then the Bill Validator (if
present) and finally the coin changer. Note that the
changer has no continuation connector, so it must
always be the last device connected.
Reconnect power to the control board.
Configuring Motors
The vend motors MUST BE CONFIGURED after any
changes in the arrangement, type, or number of
motors have been made.
1. Press the service mode switch on the control
board (Refer to Figure 3.1).
2. Using the # or the * key, scroll through the
menu to “TRAY SETUP”.