EasyManuals Logo

Anybus CompactCom M40 User Manual

Anybus CompactCom M40
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
Appendix B: Backward Compatibility 73 (114)
Attribute 30-series 40-series Change/Action/Comment
#7, Record Data Mode See Comment I&M Record data transparent mode (bit 1) is
replaced with the IM_Options command in the
Network PROFINET IO object (0Eh).
If this bit is 0 in the current implementation, no
action is needed
#13, I&M Profile ID Used for all APIs Only used for
“non-zero” APIs
In the 40-series, this attribute is only read for
submodules belonging to a “non-zero” API (e.g.
PROFIdrive profile). Constant values (F600h,
Generic Device and 0004h, Communication
Module) are used for submodules belonging to
API 0.
In the 30-series this parameter is used for all
API:s.
#14, I&M Profile
Specific Type
Used for all APIs Only used for
“non-zero” APIs
In the 40-series, this attribute is only read for
submodules belonging to a “non-zero API” (e.g.
PROFIdrive profile). Constant values (F600h,
Generic Device and 0004h, Communication
Module) are used for submodules belonging to
API 0.
In the 30-series this parameter is used for all
API:s.
#15, I&M Version Available Removed Attribute removed in the 40-series. The Anybus
CompactCom will never request this attribute.
The host application cannot influence the I&M
implemented by the Anybus CompactCom.
16, I&M Supported Available Removed Attribute removed in the 40-series. The Anybus
CompactCom will never request this attribute.
The host application cannot influence the I&M
supported by the Anybus CompactCom.
#20, Interface
description
Available Removed Attribute removed in the 40-series. The Anybus
CompactCom will never request this attribute.
#21, Module ID
Assignment Mode
Available Removed Attribute removed in the 40-series (Incremental
Module Identification removed in the 40-series).
The Anybus CompactCom will never request
this attribute.
#22, System Contact Available Removed Attribute removed in the 40-series. The Anybus
CompactCom will never request this attribute.
System Contact can now only be reached from
the network via SNMP (sysContact). Also see
SNMP MIB-II, p. 77.
#23, PROFIenergy
functionality
Available Removed Attribute removed in the 40-series. The Anybus
CompactCom will never request this attribute.
PROFIenergy is now enabled by the
application having implemented the Energy
Control Object (F0h).
Anybus
®
CompactCom
M40 Hardware Design Guide HMSI-216-126 EN 2.6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anybus CompactCom M40 and is the answer not in the manual?

Anybus CompactCom M40 Specifications

General IconGeneral
BrandAnybus
ModelCompactCom M40
CategoryConference System
LanguageEnglish