In external NTRIP software select COM port as the output device (software dependent).
Settings are identical as above under TCP/IP configuration. For the COM port settings
ensure to select the corresponding COM port on your computer and the proper baud rate.
The baud rate is usually either 19,200 or 38,400.
Start the RTK streaming. The COM port on the LVX should indicate that correction data
are received under the “Input” column.
The final check if RTK is applied can be done under the Receiver Status/Position: