USER manual46 of 216
POWER SWITCH
• Openthewatermainsvalve.
• Turn the power switch to position “1” (elec-
tricity is supplied to the pump to automati-
callylluptheappliance'sheatingunitand
steam heating unit) and wait for the heating
unittobeautomaticallylledwithwater.
• Turn the main switch to position “2” (full electricity is sup-
plied, including to the heating element in the heating
unit) and wait for the machine to warm up completely.
6.3.2 Electric heating (versions with
Display)
• Pressthemachine'smainswitch(1).
1
• Waitfortheheatingunittobeautomaticallylledwith
water, if necessary.
• Wait another second or so for the automatic test to be
carried out.
WAIT
FUNCTIONAL TEST
TEST RESULTS
- OK -
• The machine is ready for use when the following mes-
sages appear on the display:
1.0 BAR 120°C
09:16 09-10-12 5
1.0 BAR 120°C P
09:16 09-10-12 5
Time
Heating unit
pressure
Date Day of the week
Heating unit
temperature
Programming
indicator
See the days of the week reference table in para-
graph "Programming a Working Day" on page 54.
1 2
0
If the temperature inside the heating unit is lower
than 90°C (machine’s heating-up phase), the mes-
sage LOW will appear on the display.
To restart the machine, press and hold the same buttons for
3 seconds.
6.3.3 Gas heating (if a gas system
has been installed)
• Turn the power switch (A) to position 1.
• Openthegasvalve(B) on the mains.
• Press and hold the button (C) and simultaneously press
theONbutton(D).Oncetheamehasignited,holddown
the knob (C) for a few seconds, to allow the thermocouple
to activate correctly.
• Thencheckthattheamehasignitedthroughthewin-
dow (E).
• Wait for the operating pressure shown on the pressure
gauge to reach the working value of 0.1-0.12 MPa (1-1.2
bar).
AD
C BE
6.3.4 Electric + gas heating (if a gas
system has been installed)
During the machine's heating-up phase (roughly
20 minutes), the negative pressure valve will re-
lease steam for a few seconds until the valve closes.
Do not open the gas mains when the heating unit is empty.
• Proceed as indicated in the previous paragraph.
• Aftercheckingthattheamehasignited,turnthepower
switch (A) toposition 2. In this way the heatingunit's
heating element is powered and the operating pressure
will be reached more quickly.
• Wait for the operating pressure shown on the pressure
gauge to reach the working value of 0.1-0.12 MPa (1-1.2
bar).
6.3.5 Turning off the machine
Turn off the machine using the main switch or power switch.