Model X High Speed Sublimation printer
66
Reasons
Countermeasures
Signal transmission error
Check the TPC data board and sprinkler
connection harness
Problem coming from the nozzle
Re-plug the data cable, or print it with other
nozzle data lines to see if the nozzle is normal.
Check the TPC data board and sprinkler
connection harness
Reasons
Countermeasures
Machine working environment
The workshop is equipped with air conditioners
and humidifiers according to the requirements.
The workshop and the machine need to be kept
clean.
Abnormal machine negative pressure
causes ink hanging on the nozzles
surface
Check if the total air pressure of the machine is
normal, and recalibrate to a normal working
pressure of the machine.
The ink tube is worn but there is no
ink leakage, ink is hanging on the
nozzle’s surface
Replace the new ink tube
Abnormal pressure on the
electromagnetic valve causes ink
hanging on the nozzle’s surface
Replace to a new electromagnetic valve
Insufficient ink supply to the
machine
Replace the disc and vertical filters in time
Use of expired ink
Check ink inventory regularly and contact
engineer in time