02-00-30 Protective Covers
To protect the engine of corrosion it should be stored and transported in a package appropriate for
corrosion protection. Suitable corrosion protection is available at Austro Engine GmbH.
All engine openings have to be protected against ingress of dirt and moisture.
All protective covers and mountings have to be removed before taking the engine into
operation.
To avoid contamination during the installation process, the covers should be removed step
by step with installing the lines and hoses.
02-00-40 Storage
During transport and afterwards storage, following terms must be observed:
The engine has to be stored in suitable workplaces in a horizontal position, the cylinder axis must
have an angle of 34°, always covered against environmental influences and never outside. For further
information refer to the Installation Manual E4.02.01 Chapter 6 “Installation Position”.
For storage requirements refer to the Operation Manual E4-01-01. of the E4 engine or E4-
01-02 of the E4P engine.
02-00-50 Return Parts Shipping Instruction
If you have to return parts to Austro Engine, please follow these instructions:
Clean the part, especially oil contaminated arts like Governors
Tag the part with an unserviceable tag and fill all required information
Put the part in an appropriate box together with shock absorbing material e.g. bubble foil,
foam etc.
Make the box ready for shipment
If the whole engine has to be supplied back ensure that the appropriate box as described in
Chapter 02-00-10 is used