AS1635-MT-EN-03
p. 17/46
Then use the Up (SW5) and Down (SW6) buttons to change the parameter contents. Once the choice has been made,
confirm by briefly pressing the OK button, or press the left button (or wait 1 minute) to leave the sub-menu without
changing the parameters.
Important! The new values must be saved in order to permanently store them; otherwise the modifications will be lost
in the event of a power failure. (4.3.3.4. System, page 18)
md-A
md-b
: Operating mode in direction of passage A.
Operating mode in direction of passage B.
3 values are possible in direction A and direction B:
CLOS
= Lock mode
(In this direction of passage, the rotational movement of the turret is
not possible because the lock is permanently actuated)
FrEE
= Free access mode. (The rotation of the turret is free, simply by pressing on the
horizontal arm)
CtrL
= Controlled mode
(The movements are controlled by the digital inputs, which are
generally connected to the reader(s)).
Stby
: Condition of the locking mechanism in passage standby status.
NO
= (Normally open). The turret is unlocked in the waiting state. In the case of
an attempted passage without validation, the turret locks when a rotation is
detected. The turret will never lock if the authorisations precede the passage,
even in controlled mode.
This operating mode is very rarely used.
NC
= (Normally closed) This is the usual operating mode: In controlled mode, the turret
is locked while awaiting a passage authorisation. .
4.3.3.3. counters
Press briefly the Down button (SW5) to move from the SEt menu to the Cntr menu.
The key on the right (SW3) gives access to the various counters (sub-menu).
Press this key (SW3) again to access the count value.
To reset the counter to zero, hold down the key to the right for 2 seconds.
CtnA
: Number of passage authorisations in direction A
Ctnb
: Number of passage authorisations in direction B
CtEr
: Number of major errors stored
CtPA
: Number of effective passages (with rotation of the turret) in direction A.
CtPb
: Number of effective passages (with rotation of the turret) in direction B.
CtPn
: Difference between counts CtPA and CtPb. This counter is incremented during a passage in
direction A and decremented during a passage in direction B, without ever becoming negative.
Resetting counters A and B does not alter the count result.
CtrA
: Number of passage authorisation(s) in direction A stored at this time (in controlled mode)
Ctrb
: Number of passage authorisation(s) in direction B stored at this time (in controlled mode).
The value is indicated rounded for large numbers:
• From 0 to 9,999: the number is indicated as it is.
• From 10,000 to 999,9 million: the number is rounded and shown as fraction of 1 million.
For example:
• 10123: 0.001
The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using this information for any purpose other
than the use of the products or the execution of the project to which it refers and from communicating it to third parties without prior written agreement of Automatic Systems. The
document is subject to change without notice.