DJH Reviewed:
SPOC 07/08/2011
Solution & Interoperability Test Lab Application Notes
©2011 Avaya Inc. All Rights Reserved.
18 of 51
SM6-1_CMES
3.11. Configure Stations
For each SIP user defined in Session Manager, add a corresponding station on Communication
Manager Evolution Server. The extension number defined for the SIP station will be the number
the SIP user enters to register to Session Manager.
Note: Instead of manually defining each station using the Communication Manager SAT
interface, an alternative option is to automatically generate the SIP station when adding a new
SIP user using System Manager. See Section 4.10 for more information on adding SIP users.
Use the add station n command where n is a valid extension number defined in the system.
On Page 1, enter the following values and use defaults for remaining fields.
Type: Enter station type corresponding to the specific device.
In sample configuration “9630SIP” was used.
Port: Leave blank. Once the command is submitted, a virtual port will
be assigned (e.g. S0000).
Name: Enter a display name for user.
Security Code: Enter the number used to log in station.
Note: this number should match the “Communication
Profile Password” field defined when adding this user in System
Manager. See Section 4.10.
add station 50655 Page 1 of 6
STATION
Extension: 50655 Lock Messages? n BCC: 0
Type: 9630SIP Security Code: 123456 TN: 1
Port: Coverage Path 1: 1 COR: 1
Name: SIP Station User Coverage Path 2: COS: 1
Hunt-to Station:
STATION OPTIONS
Time of Day Lock Table:
Loss Group: 19
Message Lamp Ext: 50655
…
IP Video? n