50 ENGINEERING DOCUMENTATION
_____________________________________________________________________________________________
- "F..-1"- measurements,
- "F..-2"- enter product data: product code and batch size,
- "F..-3"- enter control parameters: nominal mass Qn and measurement number,
- “F..-4”- select mode for data transmission (automatic or manual).
[Entering product data]
3. Press
T
key when "F..-2" is displayed.
The following options appear successively on display:
- "Cod"- product code [6 digits],
- "n" - batch size,
- "out" - exit,
4. Press
T
key when "Cod" is displayed.
Previously entered product code will be displayed one by one with "out" option.
In order to enter new product key press
T
key when previous code is
displayed, and after
"-" appears use keys:
→0← - change digit,
T
- move to next digit,
MENU - finish.
If previous code is valid, choose "out" pressing
T
key.
5. Press
T
key when "n" is displayed.
Previously entered batch size will be displayed one by one with "out" option.
In order to enter new batch size press
T
key when previous value is displayed
using keys:
→0←
, T and MENU as above.
6. Press
T
key when "out" is displayed.
[Entering control parameters]
7. Press
T
key when "F..-3" is displayed.
The following options appear successively on display:
- "O_n"- nominal mass (Qn),
- "-20", "-60", "-100", "-160", "n" select available measurement quantity (total
quantity of samples),
- "out" - exit,
8. Press
T
key when "O_n" is displayed.
Previously entered nominal mass will be displayed one by one with "out" option.
In order to enter new nominal mass press
T
key when previous value is
displayed using keys:
→0←
, T and MENU as above.
9. Select measurement quantity pressing
T
key. Selected quantity should comply
with requirements of good packaging act of law (it depends on control kind and
batch size). Letter n denotes full control.
10.Press
T
key when "out" is displayed.
[Selecting mode for data transmission]

Table of Contents