Operation and Features
3-6 BASLER A202k
DRAFT
Case 2 - Exposure Start With Frame Valid Low
Figure 3-5: ExSync, Level-controlled Mode - Exposure Start with Frame Valid Low
If the ExSync signal falls while frame valid is low as shown in Figure 3-5:
Exposure will start after a delay of 3.7µs.
The actual length of the exposure time will be equal to the ExSync signal low time plus
94.5 µs.
As shown in Figure 3-5, FVAL must be low for at least 1 µs before the ExSync signal
falls.
exposure
Frame
Valid
Integrate
Enabled
Line
Valid
> 1 µs
EXSYNC
123100410031002
Timing
charts are
not drawn to
scale.