// Select the appropriate auto function AOI for luminance statistics
// Currently AutoFunctionAOISelector_AOI1 is predefined to gather
// luminance statistics
// Set position and size of the auto function AOI
Camera.AutoFunctionAOISelector.SetValue( AutoFunctionAOISelector_AOI1 );
Camera.AutoFunctionAOIOffsetX.SetValue( 0 );
Camera.AutoFunctionAOIOffsetY.SetValue( 0 );
Camera.AutoFunctionAOIWidth.SetValue( Camera.AutoFunctionAOIWidth.GetMax() );
Camera.AutoFunctionAOIHeight.SetValue( Camera.AutoFunctionAOIHeight.GetMax() );
For detailed information about using the pylon API, refer to the Basler pylon Programmer’s Guide
and API Reference.
You can also use the Basler pylon Viewer application to easily set the parameters.
11.12.1.3 Using an Auto Function
To use an auto function, carry out the following steps:
1. Select the Auto Function AOI that is related to the auto function you want to use.
2. Set the postion and size of the Auto Function AOI.
3. If necessary, set the lower and upper limits for the auto functions’s parameter value.
4. If necessary, set the target value.
5. If necessary, set the auto function profile to define priorities between auto functions.
6. Enable the auto function by setting it to "once" or "continuous".
For more information the individual settings, see the sections below that describe the indvidual auto
functions.