Physical Interface
Basler pilot 75
7.7.3 Output Line Response Time
Response times for the output lines on the camera are as shown below.
Fig. 28: Output Line Response Times
Time Delay Rise (TDR) = 1.5 µs
Rise Time (RT) = 1.3 - 5.0 µs
Time Delay Fall (TDF) = 1 - 20 µs
Fall Time (FT) = 1 - 5 µs
Note
The response times for the output lines on your camera will typically fall into
the ranges specified above. The exact response time for your specific
application will depend on the external resistor and the applied voltage you
use.
Camera
Output
Signal
Output
Line
Voltage
Time
TDR
RT
TDF
FT
90%
90%