Image Acquisition Control
Basler pilot 83
Camera.AcquisitionFrameRateAbs.SetValue( 60.0 );
double resultingFrameRate = Camera.ResultingFrameRateAbs.GetValue( );
// how to disable the FrameRateAbs parameter
Camera.AcquisitionFrameRateEnable.SetValue( false );
For detailed information about using the pylon API, refer to the Basler pylon Programmer’s Guide
and API Reference.
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon Viewer, see Section 3.1 on page 29.
For more information about the camera’s exposure time parameter, see Section 8.4 on page 91.
For more information about determining the maximum allowed acquisition frame rate, see
Section 8.9 on page 102.
Note
The explanations in Section 8.2.2 and Section 8.2.3 are intended to give you
a basic idea of how the use of a software trigger works. For a more complete
description, refer to the Basler pylon Programmer’s Guide and to the sample
programs included in the Basler pylon Software Development Kit (SDK).