EasyManua.ls Logo

Baumuller b maXX 1000 - Page 113

Baumuller b maXX 1000
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
113
of 208
4
P1173
The deceleration time is used to determine the time required for the b maXX
®
1000 to
decelerate from the maximum output frequency ZP0033 down to 0 Hz. The rate is linear
unless S-curve is „Enabled.“, see ZP1177.
Acceleration/deceleration time 1 or 2 can be switched by setting the external terminals
(MI3 to MI5 or MI7 to MI12) ZP1091 to ZP1093 or ZP1095 to ZP1100 to 7.
Standardization see ZP1186.
P1174
The quickstop ramp is effective in all quickstop procedures, not only in the speed-con-
trolled operation modes.
The quickstop time is used to determine the time required for the b maXX
®
1000 to ramp
from maximum output frequency ZP0033 to 0 Hz.
For a correct functioning of brake operations at the quickstop- or deceleration the speed
controller must be sufficiently parameterized.
Standardization see ZP1186.
P1176
This parameter is used to ensure smooth acceleration and deceleration via S-curve. For
further information see ZP1177.
Standardization see ZP1186.
P1173
HLG Rücklaufzeit 1 0.1 to 600.0 s or
0.01 to 60.00 s
EE RFG deceleration time 1 10.0 s
ON BM_u_RFG1RampDownTime1 10:1 or 100:1
P1174
HLG Schnellhalt-Zeit 0.1 to 600.0 s or
0.01 to 60.00 s
EE RFG quickstop time 10.0 s
ON BM_u_RFG1StopTime 10:1 or 100:1
P1176
HLG S-Kurve Hochlaufzeit 0.1 to 600.0 s or
0.01 to 60.00 s
EE RFG S-curve accel time 10.0 s
STOP BM_u_RFG1SCurveAccelTime 10:1 or 100:1

Table of Contents

Related product manuals