Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
112
of 208
4.3
P1170
Settings for ramp function generator.
m If the S-curve profile (ZP1170 ramp function generator mode bit 6 = 1) is set and
ZP1176 ZP1172 or ZP1180, ZP1177 ZP1173 or ZP1181, then the ramp
function generator accelerates and decelerates only with trapezoidal speed profile.
P1171
This parameter displays the set point first and second frequency.
Scaling before the PID control.
P1172
The acceleration time is used to determine the time required for the b maXX
®
1000 to
ramp from 0 Hz to maximum output frequency ZP0033. The rate is linear unless S-curve
is „Enabled“; see ZP1176.
Acceleration/deceleration time 1 or 2 can be switched by setting the external terminals
(MI3 to MI5 or MI7 to MI12) ZP1091 to ZP1093 or ZP1095 to ZP1100 to 7.
Standardization see ZP1186.
P1170
Hochlaufgeber Modus 0 to 120
EE Ramp function generator mode 0
ON BM_u_RFGMode 1:1
Bit Meaning
0 to 2 reserved
3 1: Negative set values inhibited
4 1: Positive set values are inhibited
5 1: Polarity reversal of the actual set value
6 0: Trapezoidal speed profile with ramp function generator smoothing
1: S-curve with square speed profile
7 ... 15 reserved
P1171
Anzeige Hochlaufgeber Eingang 0.0 to 600.00 Hz
- Display ramp function generator input 0.00 Hz
A BM_u_RFGDisplayInput 100:1
P1172
HLG Hochlaufzeit 1 0.1 to 600.0 s or
0.01 to 60.00 s
EE RFG acceleration time 1 10.0 s
ON BM_u_RFG1RampUpTime1 10:1 or 100:1