EasyManua.ls Logo

Baumuller b maXX 1000 - Page 114

Baumuller b maXX 1000
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
114
of 208
4.3
P1177
This parameter is used to ensure smooth acceleration and deceleration via S-curve.
The S-curve is disabled when set to 0.0 and enabled when set to 0.1 to 10.0/0.01 to
10.00.
Setting 0.1/0.01 gives the quickest and setting 10.0/10.00 the longest and smoothest S-
curve.
The b maXX
®
1000 will not follow the accel/decel times in ZP1172, ZP1173,
ZP1180, ZP1185.
Standardization see ZP1186.
The diagram below shows that the original setting of the accel/decel time is only for ref-
erence when the S-curve is enabled. The actual accel/decel time depends on the select-
ed S-curve (0.1 to 10.0).
The total accel. time = ZP1172 + ZP1177 or ZP1180 + ZP1177
The total decel. time = ZP1173 + ZP1177 or ZP1185 + ZP1177
Disable S-curve Enable S-curve
Figure 50: Acceleration/deceleration S-curve
P1177
HLG S-Kurve Rücklaufzeit 0.1 to 600.0 s or
0.01 to 60.00 s
EE RFG S-curve decel time 10.0 s
STOP BM_u_RFG1SCurveDecelTime 10:1 or 100:1

Table of Contents

Related product manuals