Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
114
of 208
4.3
P1177
This parameter is used to ensure smooth acceleration and deceleration via S-curve.
The S-curve is disabled when set to 0.0 and enabled when set to 0.1 to 10.0/0.01 to
10.00.
Setting 0.1/0.01 gives the quickest and setting 10.0/10.00 the longest and smoothest S-
curve.
The b maXX
®
1000 will not follow the accel/decel times in ZP1172–, ZP1173–,
ZP1180–, ZP1185–.
Standardization see ZP1186–.
The diagram below shows that the original setting of the accel/decel time is only for ref-
erence when the S-curve is enabled. The actual accel/decel time depends on the select-
ed S-curve (0.1 to 10.0).
The total accel. time = ZP1172– + ZP1177– or ZP1180– + ZP1177–
The total decel. time = ZP1173– + ZP1177– or ZP1185– + ZP1177–
Disable S-curve Enable S-curve
Figure 50: Acceleration/deceleration S-curve
P1177
HLG S-Kurve Rücklaufzeit 0.1 to 600.0 s or
0.01 to 60.00 s
EE RFG S-curve decel time 10.0 s
STOP BM_u_RFG1SCurveDecelTime 10:1 or 100:1