Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
138
of 208
4.3
P2031
To set a password to protect your parameter settings.
If the display shows 0, no password is set or password has been correctly entered in
ZP2030. All parameters can then be changed, including ZP2031.
The first time you can set a password directly. After successful setting of password the
display will show 1.
Be sure to record the password for later use.
To cancel the parameter lock, set the parameter to 0 after inputting correct password into
ZP2030.
The password consists of min. 1 digits and max. 4 digits.
How to make the password valid again after decoding by ZP2030:
Method 1: Re-input original password into ZP2031 (or you can enter a new password if
you want to use a changed or new one).
Method 2: After rebooting, password function will be recovered.
Figure 63: Password protect set
P2031
Passwortschutz 0 to 9999
EE Password protect set 0
STOP BM_u_PasswordProtectSet 1:1 -
Value Meaning
0 Display: No password set or successful input in ZP2030
1 Display: Password has been set
0 to 9999 Password settings