4.3
P0122
If temperature exceeds the motor PTC overheat warning level ZP0120, the drive will act
according to ZP0122 and display error code 0512
hex
. If the temperature decreases be-
low the result (ZP0120 minus ZP0121), the warning display will disappear.
P0123
P0124
Parameters ZP0057, ZP0061, ZP0065 and ZP0111 can only be changed if
ZP0124 = 0.
P0122
Motorüberhitzung Warnung 0
to 2
EE Motor PTC overheat warning protection 0
STOP BM_u_PTCOverheatWarning 1:1 -
Value Meaning
0 Warn and RAMP to stop
1 Warn and COAST to stop
2 Warn and keep running
P0123
Motor Nenndrehzahl/Nennfrequenz Auswahl 0
to 1
EE Motor rated speed/nominal slip master selection 1
STOP BM_u_MotorRatedSpeedSlipSelection 1:1 -
Value Meaning
0 Motor rated speed is existing, motor rated Slip can automatic calculation with ZP0124
1 Motor rated slip is existing, motor rated speed can automatic calculation with ZP0124
P0124
Motor Nenndrehzahl/Nennfrequenz Bestätigung 0
to 2
EE Motor rated speed/nominal slip master selection
confirm
0
STOP BM_u_MotorRatedSpeedSlipSelectionConfirm 1:1 -
Value Meaning
0 Motor nominal slip frequency or motor rated speed can be changed
1 Start calculation
2 Calculated motor nominal slip frequency or motor rated speed OK

Table of Contents