Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
35
of 208
4
P0240
Procedures for troubleshooting and for additional information see chapter ’Troubleshoot-
ing’ in the manual b maXX
®
1000.
Here are the five most recent faults that occurred, are stored. After removing the cause
of the fault, use the reset command to reset the drive.
Fault list:
P0240
Aktueller Fehlerspeicher 0 to 052F
hex
- Present fault record 0
A BM_u_PresentFaultRecord 1:1 -
Error code Description
(from b maXX
®
1000 controller)
Display b maXX
®
1000
Error reaction
CANopen
Error code
0000
hex
Reserve --
0003
hex
NMI interrupt has occurred - incorrect bus access oc PWM Inhibit 7400
hex
0021
hex
CAN error cPtE, cc04 to
cc08, cc02
ZP0296– 8200
hex
0030
hex
Error in analog option card AnCd 7300
hex
0035
hex
Error ADDA card break off Aoff PWM Inhibit
0050
hex
Communications error USB CARD (CME-USB01) or IO COM1
communication time out
UbCd; PE10 ZP0868– 7500
hex
0052
hex
UIC overvoltage (U
DC
) ov PWM Inhibit 3210
hex
0054
hex
Ground current GFF PWM Inhibit 2240
hex
0062
hex
Motor temperature fault - switch-off threshold exceeded PtC1 ZP0119– 7120
hex
0063
hex
Fault I2t > 100% oL1 PWM Inhibit 7120
hex
0070
hex
Communication error PG card (option card) PG_ERR ZP1077– 7300
hex
00A0
hex
1= Modbus communication time monitoring cE10 ZP0862– Warning
00A1
hex
1= control board/power board communication time monitoring cP10 PWM Inhibit 7500
hex
00B0
hex
EEPROM error cF10; cF11;
cF20; cF21
ZP1007– 5530
hex
00B2
hex
Checksum error in EEPROM Ecnt PWM Inhibit 5530
hex
0500
hex
IGBT inside temperature exceed oH1 PWM Inhibit 4310
hex
0501
hex
Lower than standard voltage Lv ZP0297– 3220
hex
0502
hex
Phase loss PHL PWM Inhibit 3130
hex
0503
hex
Password don't match codeE PWM Inhibit 6320
hex
0505
hex
Temperature sensor fault detect cF34 PWM Inhibit 4310
hex
0506
hex
Control broad ACI loss AErr ZP0806– FF00
hex
0507
hex
b maXX
®
driver loading exceed oL PWM Inhibit 2310
hex
0509
hex
Motor loading exceed oL2 ZP1213– 2310
hex
050A
hex
CC current clamp HPF1 PWM Inhibit 5000
hex
050B
hex
OV hardware error HPF2 PWM Inhibit 5000
hex
050C
hex
GFF ground hardware error HPF3 PWM Inhibit 5000
hex
050D
hex
OC hardware error HPF4 PWM Inhibit 5000
hex