4.3
P0241
Procedures for troubleshooting and for additional information see chapter ’Troubleshoot-
ing’ in the manual b maXX
®
1000.
Here are the next five most recent faults that occurred, are stored. After removing the
cause of the fault, use the reset command to reset the drive, fault list see ZP0240on
page 35.
050E
hex
DC BUS checking error cF33 PWM Inhibit 3210
hex
0512
hex
Motor PTC temperature warning PtC2 ZP0122 Warning
0513
hex
IO PID feedback error FbE ZP1368,
ZP1368
Warning
0515
hex
U-phase error cF30 PWM Inhibit 2300
hex
0516
hex
V-phase error cF31 PWM Inhibit 2300
hex
0517
hex
W-phase error cF32 PWM Inhibit 2300
hex
0518
hex
Current exceed at acceleration process ocA PWM Inhibit 2310
hex
0519
hex
Current exceed at deceleration process ocd PWM Inhibit 2310
hex
051A
hex
Current exceed at steady state ocn PWM Inhibit 2310
hex
051B
hex
Power BD over heat oH2 PWM Inhibit 4310
hex
051C
hex
External fault EF ZP0803 9000
hex
Error code Description
(from b maXX
®
1000 controller)
Display b maXX
®
1000
Error reaction
CANopen
Error code
P0241
Zweiter aktueller Fehlerspeicher 0 to 052F
hex
- Second most recent fault record 0
A BM_u_SecondFaultRecord 1:1 -