Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
38
of 208
4.3
P0296
This parameter determines the reaction after a CAN-bus drop-out.
CANopen Index 6007
hex
for Node Guarding Error
P0297
This parameter determines the reaction after a power lost.
P0296
Fehlerreaktion CAN-Bus Signalausfall 0 to 255
EE Reaction CAN-bus drop-out 0
STOP BM_u_ReactionCANBusDropOut 1:1 -
Value Meaning
255 No Reaction
0 Reaction according to ZP1007– (error reaction code)
1 Pulse inhibit
2 Braking operation at the deceleration time
3 Braking operation at the quickstop time
4 Braking operation at the deceleration automatic time
6007
hex
0
hex
No Reaction
2
hex
Pulse inhibit, default value
3
hex
Quickstop
FFFF
hex
Reaction according to ZP0296–
P0297
Fehlerreaktion Spannungsausfall 0 to 255
EE Error reaction power lost 0
STOP BM_u_ErrorReactionPowerLost 1:1 -
Value Meaning
-1 No Reaction
0 Pulse inhibit
1 Braking operation at the deceleration time
2 Braking operation at quickstop ramp
3 Braking operation at the deceleration automatic time