EasyManua.ls Logo

Baumuller b maXX 1000 - Page 97

Baumuller b maXX 1000
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
97
of 208
4
P1130
Please note the ACI/AVI switch on the b maXX
®
1000, see ZP1129from page 96.
For further information see ZFigure 44 and ZFigure 45on page 95.
P1131
Please note the ACI/AVI switch on the b maXX
®
1000, see ZP1129from page 96.
The parameter are used to set the analog input reference values and is based on percent-
age of ZP0033). For further information see ZFigure 44 and ZFigure 45on page 95.
P1132
Please note the ACI/AVI switch on the b maXX
®
1000, see ZP1129from page 96.
For further information see ZFigure 44 and ZFigure 45on page 95.
P1133
Please note the ACI/AVI switch on the b maXX
®
1000, see ZP1129from page 96.
The parameter are used to set the analog input reference values and is based on percent-
age of ZP0033). For further information see ZFigure 44 and ZFigure 45on page 95.
P1134
Please note the ACI/AVI switch on the b maXX
®
1000, see ZP1129from page 96.
For further information see ZFigure 44 and ZFigure 45on page 95.
P1130
Minimaler ACI Strom 0.0 to 20.0 mA
EE Minimum ACI current 4.0 mA
STOP BM_u_MinimumACICurrent 10:1
P1131
Minimale ACI Frequenz 0.0 to 100.0 %
EE Minimum ACI frequency 0.0 %
STOP BM_u_MinimumACIFrequency 10:1
P1132
Maximaler ACI Strom 0.0 to 20.0 mA
EE Maximum ACI current 4.0 mA
STOP BM_u_MaximumACICurrent 10:1
P1133
Maximale ACI Frequenz 0.0 to 100.0 %
EE Maximum ACI frequency 0.0 %
STOP BM_u_MaximumACIFrequency 10:1
P1134
Minimale AVI2 Spannung 0.0 to 10.0 V
EE Minimum AVI2 voltage 0.1 V
STOP BM_u_MinimumAVI2Voltage 10:1

Table of Contents