Setting the intermediate positions
4. Programming the intermediate
position/ventilation position
Run the drive to the required intermediate
position/ventilation position and press the
STOP and DOWN buttons or STOP and UP
buttons until the drive clicks once.
To travel to the intermediate position/
ventilation position, press the DOWN
button or UP button twice within one
second (double tap).
Intermediate position Ventilation position
Note:
The drive moves in dead-man mode during the installation run (initial
opening and closing movement). The drive indicates the lack of a limit position by
briefly starting up, stopping and then continuing (limit position status indicator).
Once the limit positions have been detected correctly 3 times in succession
(3 opening and closing movements), the drive definitively saves the limit
positions.
5. Deleting the intermediate
position/ventilation position
Run the drive to the position to be
deleted and repeat the programming
until the drive clicks twice.
6. Activating the anti-freeze
mechanism at the top (optional)
Run the roller shutter towards the upper
stop. Then press the programming
button until the drive clicks once. Then
press the programming button, STOP
button and UP button until the drive
clicks three times.
7. Activating the fly screen
protection function (optional)
Run the roller shutter to the upper limit
position. Then press the programming
button until the drive clicks once. Then
press the programming button, STOP
button and DOWN button until the drive
clicks three times.
1x click 1x click
1x click
3x click
1x click 3x click