General
All other drives can be identified via the programming
unit. Connect the wires in the connecting cable of
the drive to the wires of the same colour in the
programming unit.
Press the programming button
for 2 seconds.
If the drive produces a loud noise and the tube does not
turn, the drive is a type M. Replace the programming
unit immediately with one that is suitable for an M drive.
If the drive does not react or clicks once or twice, it is
an S(+), PS(+), SEB(+), SE I1, SEF I1, SF(+), PSF(+),
C12 or C18 drive type.
Press the travel button to move in both directions.
Which type of sun protection drive has been installed?
The limit positions of the latest generation of drives with
electronic limit switching can be deleted and redefined
via the existing control panel. To do this, proceed as
follows:
First, run the drive for 6 seconds in the Retract or
Extend direction.
Then perform the travel movements described oppo-
site to delete the limit positions. If the drive then clicks
twice, it is one of the following types: E18, E12 or E15.
If the drive is installed in a zip screen, it is an E18 type
drive.
To identify the types E12 and E15, move the drive in
any direction.
If the drive stops after roughly 3 seconds then continues
running, it is an E15 type drive.
If the drive stops after roughly 10 seconds then continues
running it is an E12 type drive.
1 s
1 s
1 s
1 s
1 s
1 s
1 s
5 s
Deleting the limit positions