7
Roller shutter
Drives
Turn the drive roughly 3 revolutions then press the
programming button again for 2 seconds (the drive
clicks again to indicate that a second limit position
has been set). Turn the drive roughly 1.5 revolutions
in the opposite direction and carry out the deletion
sequence:
- Press and hold the programming button
- Press and hold the button
- Release the programming button
- Press the programming button again until the drive
clicks twice.
If the drive does not react, it is an RF(+) (up to 2002),
PRF+ (2003–2009), PROF+ (from 2009 onwards),
C01 (from 2013 onwards) or B01 (from 2012) drive
with integrated radio receiver and bidirectional radio
control. The drive type can be identified by program-
ming the corresponding hand-held transmitter.
If the drive clicks twice, it is an RP(+), RO(+) or PR+
drive type.
Press the programming button
again.
If the drive clicks twice again, it is an RO(+) (from 2010
onwards).
If the drive clicks once, it is a RP(+) or PR+ drive. You
have now programmed a limit position. Turn the drive 3
revolutions from the limit position.
If the drive runs without stopping, it is a PR+ (from 2003
onwards) drive.
If the drive stops and continues running, it is a PR+
(from 2009 onwards) drive.