91
Short! Short! Short! Short!
Short! Short! Short! Press
and
hold!
2. Setting the Retract limit
position using the operator
control
To upper stop
Run the shading solution towards
the upper stop until the drive
stops automatically.
To upper point
Run the shading solution to the
upper limit position
. Then
move the shading solution in the
Extend direction briefly twice,
waiting for 1 second between
movements, then in the Re-
tract direction until the drive
stops automatically and clicks
once after 3 seconds .
1. Setting the Extend limit
position using the operator
control
To lower point
Run the shading solution to the lower
limit position
. Now move the shad-
ing solution up briefly twice, waiting
for 1 second in between movements,
then back down until the drive
stops automatically and clicks once
after 3 seconds .
3. Deleting the limit positions
using the operator control
Run the drive for 6 seconds in the
Retract or Extend direction.
Then run through steps to of the
deletion sequence shown opposite
at one second intervals until the drive
clicks twice.
When using operator controls with
maintained operation mode, a STOP
command must be issued after
every short drive command.
Setting the limit positions using the operator control
Sun protection
Drives
1x click
1x click