BestCode Next Series 8 Technical Manual October 2022 Page 113 of 290
3. Pulse the valve on and off repeatedly
from the Fluidic screen.
DO NOT RUN THE PUMP! If
the system is 88SOP or
88SHSOP, disconnect the
pump cable from the main
board before servicing with
power on.
4. If valve does not click, turn off the valve,
then disconnect the valve cable
connection.
5. Remove the coil body, and submerge the
valve body in cleaner. Wait for 5-10
minutes.
6. Re-assemble the valve and install the
valve cable.
7. Repeat Step 3. If the Valve will not open
after this process, discard and replace
the valve.
8. With the Valve Open, spray Cleaner
through the valve until it runs clean.
See installation guide here