BestCode Next Series 8 Technical Manual October 2022 Page 17 of 290
Commissioning
The commissioning process is a 90-120 minute step by step guide for installing and preparing the Next Series 8 CIJ for
production operation. A video guide is available here: https://youtu.be/fLm1R5ERwo8
Make sure the Next Series 8 Controller is properly mounted. See here for instructions.
WARNING
EQUIPMENT DAMAGE: Do not run the pump until the Pre-Power Up Guide is completed.
Pre-fluid test
Procedure Time: 5 Minutes
1. Navigate to the fluidic screen
Home > Service > Fluidic
2. Press each valve button one at a time
and listen for the click.
Note: Valve 1 Printhead will click
when activated and de-activated since it
is a 3 way. Listen for a Click-Clack when
cycling the valve on and off.
Valve Troubleshooting Here
Commission the Ink Type
Procedure Time: 5 minutes
1. Navigate to the SmartFill Technician
Screen
Login as Technician
>Service>Tools>Technician>Smartfill
2. Select the ink type that matches the ink
to be installed and save
3. Press the Commission System button to
Save
4. Check the Help Screen to confirm

Table of Contents