BestCode Next Series 8 Technical Manual October 2022 Page 28 of 290
Shift Codes
Adds codes for tracking plant shift and shift at the time of Print. Can be programmed in the
Advance Message Settings
Video Guide for Shift Codes: https://youtu.be/tQP9Z1Vem5g?t=518
User Define
Codes that prompt the operator for Text when the message is selected. Easy to use for systems where messages are similar
from product to product and only require slightly varied data.
Video Guide for User Defined Fields: https://youtu.be/QAO79l8OuAE?t=713
ID:
On screen prompt for what data to enter
Length:
The total length of the programmable code
Keep user data:
When enabled, pressing the User Define button will pull up the user define screen with the
previously entered code still typed in. Saves time when only minor changes to the code are
necessary.
Allow Partial Entry:
Allow or disallow entry of less than the number of characters defined by the Length entry.
Block Field
Video Guide for Block Fields: https://youtu.be/hnQj71DZ-qo
Example
Block Length:5
Gap: 2
Block Length
Specifies the number of rows of full vertical print
Gap
Specifies the number of blank rows after the print