BestCode Next Series 8 Technical Manual October 2022 Page 156 of 290
Event Messages and Prompt Resolutions (01.06.00.00+)
Displayed when the user touches the phase icon, or its location, pm the main window to show current
phase status: Phase Point, Width, Quality, Efficiency, and Threshold.
Displayed when the user touches the USB icon on the main window to show the version of software
on the currently inserted USB drive (if any).
Displayed when the user touches the Encoder icon, or its location, on the main window to show
current encoder settings.
“An unknown error has occurred”
Displayed when an unexpected error condition occurs. Should never appear.
Fluid not detected in gutter.
Perform Backflush Nozzle then start jet, repeat up to 7 times
Clean the printhead and ensure jet is entering the gutter
Clogged gutter line. Test valve, gutter detect, venturi, and printhead gutter for clogs or obstructions.
Clean each component and replace if necessary.
Bad jet alignment. Perform nozzle alignment.
Perform Nozzle Flow Test, check for clogged components.
Press OK to Shut Down the machine
Press Cancel to close the prompt.
The message will be erased. Are you sure?
Press OK to delete the message
Press Cancel to close the prompt.