BestCode Next Series 8 Technical Manual October 2022 Page 145 of 290
4. Pull the white tube out from the back
end of the gutter detect.
5. Cut back half of the swaged yellow
tube.
Failure to steps 5-8 will
result in leaks from the
barb and tube.
Before Cutting
Cut location
After Cutting
6. Place the clipped back tube onto the
new gutter detect tube.