BestCode Next Series 8 Technical Manual October 2022 Page 192 of 290
Run with Solvent Add
After the viscosity check, the system will decide whether to add solvent.
Solvent Add Flow Logic: Active Valves: Printhead, Gutter, Solvent Add.
1) The Basic Flow Logic Loop is Occurring.
2) A Viscosity Check was just finished and determined that the Ink is thickening.
3) Solvent Add Valve activates for 1 second, then de-activates.
4) This Solvent Add Valve on/off cycle occurs 5 to 6 times in succession depending on Ink thickness.