BestCode Next Series 8 Technical Manual October 2022 Page 199 of 290
Step 3:
Place the Black tube into a
graduated cylinder.
Step 3:
Open the gutter valve and
printhead valve and set the
pressure to 40 PSI.
Step 4:
Inspect the Black tube outlet. There should be no flow.
Flow at this point would indicate a faulty bleed valve.