101
Figure 3.53 Save to CSV Screen
To save CSV files to USB flash drive, follow the steps below:
1. Press the “SAVE/RECALL” button to enter SAVE/RECALL”
menu.
2. Press the “Type” option button to select “CSV”.
3. Insert USB flash drive to USB host port of the
oscilloscope and wait that the oscilloscope has initialized
USB flash drive (about five seconds).
4. Press the “Data Depth” option button to select
“Displayed” or “Maximum”.
5. Press the “Para Save” option button to select “On” or
“Off”.
6. Press the “Save” option button then you’ll go into the
Save/Recall interface
7. Create a file name then press the “Confirm” button
(within 5 seconds, there will be a message “Save data
success” displayed on the screen). Now the CSV file has
been saved to the USB flash drive.