3.3 Inspection of Gas Circuit
First of all, make sure that there is gas in your gas supply device, and check each gas circuit and interface to see if they are
connected. Turn on the switch of each gas supply device, and turn on the switch on the oxygen gauge and the nitrogen
gauge respectively. It is recommended to rotate the switch of the oxygen gauge to 0.3-1.0Mpa and that of the nitrogen gauge
to 1.0-2.5Mpa, if the sound of air leakage is heard, search for its position, and solve the problem of air leakage.
After ensuring that there is no air leakage, click the N2 or O2 button in the operation software to confirm whether the air is
out, and then click the N2 or O2 button to confirm whether the air is off. If there is any abnormality, it needs to be solved.
3.4 Motion unit test
Open the software (after opening the software, the prompt of returning to the original point will pop up, please click the
Close button). Find out the software movement control button, check if the movement mechanism (X, Y, Z axis, etc.) can
normally run at a low speed, and move to the limit switch to test if all limit switches are valid.(If the machine has additional
functions, make the corresponding tests)
If there is an alarm in the z-axis direction at the top of the software interface, it needs to be solved through calibration. If
there is any other alarm, please check the alarm content and find the possible problem. If it cannot be solved, please contact
us. When all the movements become normal, click Go Home in the Processing menu bar tabs, and return to the original
point; or restart the software, and click on All Axes when the prompt of returning to the original point pop up.
3.5 Test of Light Emission
According to the power-on procedure on the laser source, turn on the laser control, click the "Burst" button to test the
emission of laser light, and make sure that before testing the water-cooling machine is turned on , and oxygen and nitrogen
can be normally blew off.
In general, turn on the water-cooling machine, and then open the optical fiber device. Namely, when the water-cooling
machine and the fiber optic device are on standby, turn on the switch knob of the water-cooling machine, and then turn on
the key switch and switch button of the optical fiber device when water supply becomes normal.
However, attention should be paid to the following points:
1) When water temperature is lower, after it rises to 20, open the optical fiber device.