91
Maintenance Points 3
Tip: Please follow the manufacturer's instructions for detailed introduction and operation of water cooler and laser.
1.6 Maintenance of electrical parts and electrical cabinets
1.6.1 Overview
Electric cabinet layout:
Job nature: Replace cooling water.
Interval: once/every six months
Tools/Materials: Cleaning cloth, screwdriver, Ionized/distilled
water
Job description: Remove the rear downside Cover of the
water-cooling machine, open the Water Outlet,
unscrew the Filter, completely discharge
cooling water in the filter; completely discharge
cooling water in the water-cooling machine
inner, and then add cooling water in the Water
Inlet according to water level displayed on the
water gauge, note that cooling water must be
deionized/distilled water specified by the laser
manufacturer.

Table of Contents