2.6.2 Air supply
Laser cutting machine needs to be equipped with a separate air compressor.
The requirements of the air compressor are shown in Table 2-3.
Table2-3 Air compressor requirements
Low power
High power
Ultra high power
Pressure
1.6MPa
1.6MPa
1.6MPa
Flow
1.5m
3
/min
2.6m
3
/min
3.7m
3
/min
Pressure dew point
28
28
28
Filtration accuracy
0.01μm
0.01μm
0.01μm
Oil content of air outlet
0.003ppm
0.003ppm
0.003ppm
The gas quality complies with ISO 8573-1:2010 standard requirements, solid particles-grade 2, water-grade 4, and oil-grade
3. It is required to be clean, free of water, oil and other impurities. It is used for thin carbon steel and thin stainless steel
where conditions permit.
Disclaimer: The use of compressed air below the above requirements will cause irreversible pollution to the machine
tool pipeline, air valve and cutting head. The resulting losses and various costs are borne by user and are not within
the scope of Bodor Laser's responsibility.
2.7 Residual risks and safety labels
2.7.1 Residual risks
The residual risks of the machine are as follows.