www.bodor.com/service@bodor
.com
For i series products, the foundation needs to be made pursuant to the requirements of foundation drawings (see the
Annex Foundation Drawings for i Series Products). Bodor shall not be responsible for poor cutting accuracy of the
equipment, ripples generated by cutting parts, waves and other phenomena due to the customer’s failure to make the
foundation according to the requirements!
Requirements for environment
1) The equipment should be kept dry, well-ventilated, the ambient temperature is between 5
℃
-40
℃
, and the relative
humidity is below 70% (no freezing or condensation is allowed), because the electrical parts can be below 2000 m above
sea level on average. It is recommended that capable customers provide constant temperature and humidity environment
for the equipment. When the device is powered off, the ambient temperature at the installation site must not drop below
+4
℃
. Note: Avoid thermal deformation caused by direct sunlight on one side or wind on the other side (for example,
install blinds in window positions to avoid these situations)
2) The core parts of the machine tool, including the control unit, servo unit, monitor and control panel, have certain
requirements for the environment. Protect the machine tool against interference from electromagnetic wave, When there
are electric welding and electrical discharge machining nearby, the equipment must be powered off and cannot continue
to work, failing which Bodor will not hold responsible.
3) In order to ensure cutting quality, it is necessary to ensure that there are no particles or substances which can absorb the
ray with a wavelength of 1.064um around the machine, such as solvent vapor that is emitted during paint spraying or
steam from a deoiler.
4) In the electric control cabinet, the user shall neither connect external wires and sockets nor connect electric drills,
angle grinders, etc. into the electric control cabinet, failing which Bodor shall not be liable for the damage to the
components caused thereby.
1.2 Power Supply
Quality of power supply
1) Degree of three-phase unbalance <2.5%, line voltage fluctuation <5%.
2) If the quality of power supply does not meet the said configuration, a voltage stabilizer shall be added to ensure normal