Inspection and maintenance
Inspection Tests Maintenance Acceptance Rejection
Drive/gear shift
Chain/cassette/
pinion/chainring
6 months Check for damage Check for
damage
O.K. Damage Refasten if necessary
or replace as speci-
fied in parts list
Chain guard/
spoke guard
6 months Check for damage Check for
damage
O.K. Damage Replace as specified
in parts list
Bottom bracket
axle/crank
6 months Check mount
fastening
Check mount
fastening
O.K. Loose Retighten screws
Pedals
6 months Check mount
fastening
Check mount
fastening
O.K. Loose Retighten screws
Shifter
6 months Check mount
fastening
Check mount
fastening
O.K. Loose Retighten screws
Shift cables
6 months Check for damage Check for
damage
O.K. Loose and
defective
Adjust shift cables;
new shift cables if
necessary
Front derailleur
6 months Check for damage Check for
damage
O.K. Gear shift diffi-
cult or not
possible
Adjust
Rear derailleur
6 months Check for damage Check for
damage
O.K. Gear shift diffi-
cult or not
possible
Adjust
Electric drive system
On-board
computer
6 months Check for damage Check for
damage
O.K. No screen,
defective
screen display
Restart, test battery,
new software or new
on-board computer,
decommissioning,
Control panel
6 months Check control panel
for damage
Check for
damage
O.K. No response Restart; contact
control panel manu-
facturer, new control
panel
Tachometer
6 months Calibration Speed meas-
urement
O.K. Pedelec travel-
ling 10% too
fast/slow
Take pedelec out of
service until the
source of the error is
found
Cabling
6 months Visual inspection Visual inspec-
tion
O.K. Failure in
system,
damage,
kinked cables
New cabling
Rechargeable
battery
6 months First examination see Section
Assembly
O.K. Error message Contact battery manu-
facturer; take out of
service, new battery
Battery mount
6 months Firmly in position,
lock, contacts
Check mount
fastening
O.K. Loose; lock
doesn't close,
no contacts
New battery mount
Motor
6 months Visual inspection
and mount
Check mount
fastening
O.K. Damage, loose Refasten motor,
contact motor manu-
facturer, new motor;
take out of service
Software
6 months Check version Check software
version
In latest
version
Not latest
version
Import update
Components Frequency Description Criteria Measures if rejected