Clause / Requirement Compliance Signature
Access level 3 is intended for
installers and/or configurators of
the Plena Voice Alarm System. It
provides access for configuration
and diagnosis of the Plena Voice
Alarm System. This level of access
is offered through:
The PC interface offered by
the configuration program of
the controller. A user name
and password need to be
provided to get access to this
interface.
Physical access control by
means of installing the system
elements in a restricted
environment, such as placing
the 19”-units in a 19”-rack
with key lock. This type of
access can be used for
physical diagnosis of the
system, e.g. inspect
interconnections.
Access level 4 is intended for
maintenance personnel of the
Plena Voice Alarm System. It
provides software/firmware
upgrade of the Plena Voice Alarm
System components after logical
identification. This level of access
is offered through:
The file transfer application of
the Plena Voice Alarm System
to transfer message sets to
the controller and upgrade the
system software. A password
is needed to be able to use
the File Transfer Application
and get access to the
controller.
a all mandatory indications shall be
visible at access level 1 without prior
manual intervention (e.g. the need to
open a door);
All indicators of the Plena Voice
Alarm System can be visible at
access level 1. The installer is
responsible for correct
implementation of this
requirement.
Plena Appendices | en 175
Bosch Security Systems B.V. Installation and Operation manual 2013.07 | V2.0 |