114 en | Security PRAESENSA
2020-09 | V1.20 | PRAESENSA 1.20 Configuration manual Bosch Security Systems B.V.
2. Below the System security page, click the + of the Reconnect factory default devices
category row:
Make sure that all network devices to be reconnected are reset to default and
correctly (wired) connected. See also
Show disconnected devices, page 114
.
3. Click the Reconnect button:
Reconnected devices will be connected again.
4. Check if all reconnected devices are connected now. See
Show disconnected devices,
page 114
:
If reconnected devices are still listed in Show disconnected devices, visual check and
reconnect the devices, again and repeat previous steps.
See also
System composition, page 40
.
7.1.3 Show disconnected devices
Use this function if you want to check/see if devices need to be reconnected. Notice that
reconnecting and visibility of a network device only works when it was already added and
visible in
System composition, page 40
.
To do so:
1. Below the System security page, click the + of the Show disconnected devices category
row:
Make sure all network devices are correctly (wired) connected. See also
Reconnect
factory default devices, page 113
.
2. Click the Refresh button:
Disconnected devices will be listed by Name, Hostname and location (if entered).
See
Reconnect factory default devices, page 113
and/or
System composition, page
40
.
7.2 Open interface
At startup, the PRAESENSA system controller generates a number of certificates. One
certificate is used to setup the TLS (secure) connection and offers an Open Interface client to
make sure it communicates with the right PRAESENSA system controller.
To do so:
1. Below Security, click Open interface:
2. Click the Download certificate button:
Depending on the web browser type (e.g. Firefox, Edge, etc.) you will be asked to
open/install/save the .crt file.
Follow the onscreen instructions.
3. Activate the certificate on your PC and follow the onscreen instructions.
4. Go to >
Optional: Using the Open Interface, page 132
IMPORTANT: each time the PRAESENSA system controller is reset to default, the system
controller generates new certificates. In that case, the previous described procedure needs to
be done, again.