PRAESENSA Configure the system | en 85
Bosch Security Systems B.V. Configuration manual 2020-09 | V1.20 | PRAESENSA 1.20
Operation type Description
operation is used for triggering events (for example, to
cancel a selection) and actions with a significant duration
(for example, an announcement).
Abort phased announcement The action is stopped when the external contact closes.
This type of operation is used for stopping actions that
were started with a Do once operation.
Finish phased announcement The action is stopped when the external contact closes.
This type of operation is used for stopping actions that
were started with a Do once operation.
Make phased announcement The action coupled to a virtual control input of the
system controller is started/stopped/aborted depending
of the trigger by the Open Interface.
Toggle The action coupled to the button is started when the
contact closes and stopped when the contact closes
again.
Refer to
– Assigning a function, page 85
5.7.2 Assigning a function
The function determines which function is triggered if the control input or button becomes
active. The operation that can be assigned to a control input or button, depends on the
function. A function is always linked to an operation. See
Assigning an operation, page 84
.
The available type of functions, and with which device functions are used, are represented in
the following tables:
Device Device abbreviation
(in next "Function" table)
Call station CS
Call station extension CSE
System controller SC
Multifunction power supply MPS