92 en | Configure the system PRAESENSA
2020-09 | V1.20 | PRAESENSA 1.20 Configuration manual Bosch Security Systems B.V.
5.7.4 System controller
On the Action definitions page of the system controller, the virtual control inputs could be
defined, which could be used by the Open Interface.
1. Below the Action definitions configuration page, click system controller:
– A screen appears with an overview of the connected system controller(s).
2. Select and click the name of the system controller to be configured.
– A row called virtual control inputs appears.
3. Click the + of the virtual control inputs row:
– A screen appears listed the VCIs each with the following items:
Item Value Description
VCI (n) Static text Shows the name of virtual control input which is
entered in section
System controller, page 43
> VCI
paragraph.
Function name Static text Shows the name of the Function which is selected in
section
System controller, page 43
> VCI paragraph.
Call definition Selection Select the call definition which is created in section
Call definitions, page 81
Zone / Zone groups Selection Select the zone or zone group which is created in
section
Zone definitions, page 75
> and < Buttons Using the > and < buttons, a selected zone or zone
group (left area box) can be added to, or removed from
the assigned zone or zone groups (right area box).
Submit Button Click the Submit button to store the settings: Notice
that you always have to Save the configuration. See
Save configuration, page 102
Configure a virtual control input action
See
Assigning a function, page 85
for Function (action) and
Assigning an operation, page 84
for operations available for the system controller.
Each created virtual control input (VCI) for the system controller is listed and can be individual
selected and configured. To do so:
1. Select the call definition from the dropdown list.
2. Select zone or zone groups from the dropdown list.
3. Select and move the zone or zone groups from the left area box to the right area box by
using the > button.
– Removing a zone and zone groups will be done in the reversed order by using the <
button.
4. Click the Submit button to store the settings. See also
Save configuration, page 102
.